TCB1000-PM2.5 pm10 dust concentration detector

TCB1000-PM2.5 pm10 dust concentration detector

Add fixed particulate monitoring to a site control system.

  • Read local conditions

    The display and alarms show particulate status at the monitoring point.

  • Feed a controller

    Specify the 4–20 mA or RS-485 interface needed by the site.

  • Plan the inlet

    Choose a suitable location and maintenance access for reliable sampling.

Sampling design and PM size channels must be confirmed for the supplied TCB1000 version.

Overview

The TCB1000 dust concentration detector converts airborne dust concentration signals into digital signals, employing a three-wire (4~20) mA current signal/RS485 four-wire bus digital signal output method. It features long transmission distance and excellent anti-interference performance.

The TCB1000 dust concentration detector is a particulate matter analyzer manufactured using self-suction sampling technology based on laser scattering principles. It primarily detects suspended particles in the air (PM1.0, PM2.5, PM10) or large particulate dust, coal dust, airborne dust, and cement dust, with data output presented in concentration-weighted mode.

The instrument employs advanced embedded technology, with the central processing unit (CPU) handling data acquisition. It features high processing speed, strong interference resistance, and superior measurement accuracy. This detector utilizes a full Chinese LCD display, high-precision laser dust concentration detection sensor, high-precision data processor, and high-power safety power supply.

This product is suitable for use in Zone 1 or Zone 2 environments containing explosive mixtures with Class II A to II C and temperature groups T1 to T6. A dust-tight enclosure is required for Zones 21 and 22.

Key Features

Dust Sampling & Local Alerts

  • Pump-suction sampling detection
  • Integrated audible & visual alarm
  • Flameproof Design
  • Modular Sensor Design for Easy Replacement & Maintenance
  • Laser Scattering Principle
  • Fast Response & High Sensitivity

Signal Outputs & Integration

  • 2-Channel Switch Quantity Output
  • Optional 4-20mA Signal or 4-Bus Signal

Installation, Protection & Service

  • Infrared remote control operation
  • IP67 protection grade
  • Independent wiring terminal unit
  • Stable & Reliable
  • Dual-Chamber Design
  • OEM & ODM & OBM:

Technical Specifications

Test medium  dust
Sampling method  natural diffusion
Detection principle  laser scattering
Display method  digital display / LCD display
Measuring range  1μg/m³~1000μg/m³; 1mg/m³~1000mg/m³ (other ranges optional)
Resolution  1mg/m³, 1μg/m³
Alarm setpoint  100μg/m³ (varies by detected type)
Operating voltage  DC24V/AC220V±15%
Response time T90  ≤30s
Ambient temperature  -40℃~+70℃ (digital display); -25℃~+55℃ (LCD display)
Relative humidity  20~93%RH, non-condensing
Ex certificate No.  CCR125.1416X
Ex mark  Ex db IIC T6 Gb / Ex tb IIIC T80℃ Db
Protection grade  IP67
Output signal  4-20mA / RS485
Product dimension  150×140×73 mm
Connection cable  3-wire RVVP≥3×1.5mm²; 4-bus RVVP≥4×1.5mm²

Videos

Request a Quote

Tell us the particle sizes, range, sampling/inlet needs, controller input, power and quantity.

    User Type:

    Country: