CCR R-4OX Industrial Oxygen Sensor

CCR R-4OX Industrial Oxygen Sensor

Select an oxygen sensing element for a compatible fixed gas detector.

  • Verify the mechanical fit

    Check the 32 mm form factor and mounting details against the host instrument.

  • Match the electrical signal

    Review output and load requirements before integration.

  • Plan service

    Confirm calibration and replacement intervals for your operating environment.

Compatibility and service life depend on the host instrument and supplied sensor revision.

Overview

The CCR R-4OX is a 32 mm oxygen sensing component intended for compatible fixed gas detectors. Match the mounting dimensions, output signal and load to the host instrument before ordering.

Confirm the required oxygen range, calibration procedure and service conditions for the supplied sensor revision.

Key Features

Sensor Construction & Reliability

  • Robust design
  • Proven reliability and high performance

Technical Specifications

Output signal

0.10 ± 0.03 mA

Zero Current (Offset)

< 0.6% vol. O2

T90 Response Time

< 15 seconds

Measurement Range

0 – 25% Oxygen

Maximum Overload

30% Oxygen

Linearity

Linear

Recommended Load Resistor

100 ohms

Environmental Details:

Temperature Range Continuous

-30oC to +50oC

Pressure Range

800 to 1200 mbar

Operating Humidity Range

5% to 95% RH

Important Note:

All performance data is based on conditions at 20oC, 50%RH and 1 atm, using CCR Scientific recommended circuitry.

Sensor performance is temperature dependent, and please contact CCR Scientific for temperature performance other than 20oC.

Lifetime Details:

Long Term Output Drift

< 5% per annum

Recommended Storage Temp

0oC to 20oC

Expected Operating Life

> 24 months in air

Standard Warranty

24 months from date of dispatch

Intrinsic Safety Data:

Maximum current in normal operation (pure O2)

0.01 A

Maximum o/c Voltage (10 to 100% O2)

0.9 V

Maximum s/c Current (10 to 100% O2)

0.5 A

Toxic gases at TLV levels will have no cross-sensitivity effect on CCR-Scientific oxygen sensors. At very high levels (i.e. percent levels), highly oxidising gases (e.g. ozone, chlorine) will interfere to the extent of their oxygen equivalent, but most other commonly occurring gases will have no effect.

Acid Gases

IMPORTANT NOTE: Acid gases such as CO2 and SO2 will be absorbed by the electrolyte and tend to increase the flux of oxygen to the electrode. This gives an enhanced oxygen signal of approximately 0.3% of signal per 1% CO2. CCR Scientific oxygen sensors are not suitable for continuous operation in concentrations of CO2 above 25%.

Request a Quote

Tell us the oxygen range, detector design, output/load requirements, environment and quantity.

    User Type:

    Country: