TCB2-W Wireless Gas Detection Alarm

TCB2-W Wireless Gas Detection Alarm

Monitor a fixed gas point and send alarms or readings through the selected wired or wireless connection.

  • See a local warning

    Configurable thresholds and integrated sound/light indication help personnel recognize a changing gas reading nearby.

  • Plan remote visibility

    The listed 4G/5G transmission and cloud options support off-site monitoring when available in the chosen version.

  • Keep commissioning practical

    Diffusion sensing, field calibration and infrared remote operation support setup and routine checks.

IP66 protection class. Confirm gas, power, network coverage, output wiring and remote-monitoring configuration.

Overview

The TCB2-W wireless gas detector is an advanced instrument developed by our company. Featuring high-performance gas sensors and microcontroller technology, it is manufactured using precision SMD (Surface-Mount Device) technology. This device offers excellent repeatability, reliable temperature and humidity performance, strong anti-interference capability, extended service life, and user-friendly operation. This product is designed for gas leak concentration detection in industrial and commercial settings. It converts airborne gas concentration signals into electrical signals and supports wireless communication via LoRa/4G/NB technologies. The system can upload gas concentration data and anomaly types to control hosts or cloud platforms through scheduled or event-triggered alerts, featuring long-range transmission and simplified wiring. This product is designed for gas safety detection, alarm, and control in environments containing flammable gases, including petroleum refining, chemical processing, storage and gas stations, gas pipelines, municipal utility tunnels, fire monitoring systems, and spray painting rooms. It is suitable for hazardous areas with explosive flammable gases classified as Grade II A to II C and temperature ranges from T1 to T6.

Key Features

Gas Sensing & Local Warnings

  • Customizable Alarm Setpoints
  • Fast response speed
  • Diffusion detection
  • Integrated audible & visual alarm
  • Flameproof Design
  • Wide Gas Selection
  • High Sensitivity & Stable Reliability

Control-System Signals & Connections

  • DC24V/AC220V pulse relay
  • 4G/5G data transmission
  • 2-Channel Switch Quantity Output
  • Optional Signal Upload to Host
  • Upload to Smart Cloud Platform

Installation, Power & Service

  • Infrared remote control operation
  • On-Site Calibration
  • IP66 Waterproof & Dustproof
  • OEM & ODM & OBM :

Technical Specifications

Applicable gas  Ex, toxic hazardous gas, O2 etc.
Sampling method  natural diffusion
Detection principle  catalytic bead, electrochemical, infrared, laser, semiconductor etc.
Measuring range  0~100%LEL (combustible); 0~100ppm (toxic), according to gas type
Accuracy  ±3%FS (combustible), according to gas type
Display method  LCD / digital display
Alarm  audible & visual alarm
Operating voltage  AC220V±10%, DC24V±15%
Response time  ≤30s Ex), (according to gas type)
Ambient temperature  -40℃~+70℃ (combustible); -25℃~+55℃ (toxic)
Relative humidity  20~93%RH, non-condensing
Output signal  4G wireless data upload function
Ex certificate No.  CCRI25.1415X
Ex mark  Ex db IIC T6 Gb / Ex tb IIIC T80℃ Db
Protection grade  IP66

Videos

Available Gases & Detection Ranges

The gases and ranges below are configuration options. TCB2-W Wireless Gas Detection Alarm; confirm the final sensor combination and ranges with our team.

Common Gas Parameter listing
Gas detected Measuring Range Optional Range Resolution Rat Response Time
LEL -combustible gas 0-100%LEL 0-100%VOL (Infrared or catalytic ) 1%LEL/1%vol ≤10s
carbon monoxide 0-1000PPm 0-500/2000/5000PPm 0.1/1PPm ≤10s
TVOC 0-100PPM 0-100PPM 0.1PPm/1PPM ≤15s
hydrogen 0-100%LEL 0-1000PPM 1%LEL/1PPM ≤15s
natural gas 0-100%LEL 0-100%LEL 1%LEL ≤10s
Oxygen-O2 0-30%VOL 0-30%、0-100%VOL 0.1%vol ≤10s
ozone 0-10PPm 0-20、100PPm 0.01PPm/0.1PPM ≤15s
hydrogen sulfide-H2S 0-100PPm 0-50、200、1000PPm 1/0.1PPm ≤10s
Methane-CH4 0-100%LEL 0-100%VOL 1%LEL/1%vol ≤10s
fluorine 0-10PM 0-1、10PPM 1/0.1PPm ≤15s
hydrogen chloride 0-20PPm 0-20/50PPm/100PPM 0.01/0.1PPm ≤15s
Nitrogen-N2 0-30%VOL 0-30%VOL、100%VOL 0.1%LEL/1PPM ≤10s
hydrogen 0-100%LEL 0-1000PPm 1%LEL/0.1PPm ≤15s
chlorine 0-20PPm 0-10、100PPm 0.1PPm ≤15s
ammonia gas 0-100PPm 0-50、500、1000PPm 1/0.1PPm ≤15s
oxynitride 0-20PPm 0-50、1000PPm 0.1/1PPm ≤15s
methanal 0-20PPm 0-50、100PPm 1/0.1PPm ≤15s
sulfur dioxide 0-20PPm 0-50、1000PPm 0.1/1PPm ≤15s
nitric oxide 0-250PPm 0-500、1000PPm 1PPm ≤15s
nitrogen oxide 0-20PPm 0-50、1000PPm 0.1/1PPm ≤15s
phosphine 0-20PPm 0-20、100PPm 0.1PPm ≤15s
acrylonitrile 0-100PPM 0-100PPm 0.1/1PPm ≤15s
carbon dioxide 0-5000PPm 0-1%/5%/10%VOL(Infrared ) 1PPM/0.01%VOL ≤15s
hydrogen fluoride 0-10PPm 0-1、10、50、100PPM 0.01/0.1PPm ≤15s
Xylene/methylbenzene 0-20PPm 0-5、10、50、100PPm 0.01/0.1PPm ≤15s
oxirane 0-100PPm 0-100PPm 1/0.1PPm ≤15s
For other gases and measuring ranges, please contact us directly!
Note: Not all gases and range are listed, if you need more information, please contact us.